Automatic Rotor Recognition Overspeed Door Cover Self-Locking Serum
Separation High Speed Refrigerated Centrifuge
High Speed Refrigerated Centrifuge Features:
• Easy programming to achieve high accuracy of speed control
• Easy operation with intuitive menu and easy-to-read display
• Rotor speed can be set and displayed by RPM or G-force
• Maintenance-free brushless DC motors
• Quick spin function with press and hold pulse key
• Lid with electric lock and automatic release function saves
processing time and prevents samples overheating
• Automatic self-diagnosis on startup showing accumulative running
time and last running parameters
• Microcomputer control, DC brushless motor drive, stable operation,
low noise and high speed precision.
Max RCF | 19470×g |
Max Speed | 16800r/min |
Max Capacity | 4×100mL |
Standard rotor | 12×1.5/2.0mL |
Temp control range | -20℃~40℃ |
Noise level | ≤60dB(A) |
Power supply | AC220V 50Hz |
3H16RI high speed refrigerated centrifuge using the matters needing
attention:
1. when using a variety of high speed refrigerated centrifuge, it
must first obtain the precision to balance the centrifugal tube and
balance on its contents, the difference between the balance weight
must not exceed the range of the centrifuge instruction on
regulations, each centrifuge turned to have their own allow
difference, turn a pipe must not be loaded in the singular, when
turned only partially loaded, pipe must be symmetrically placed in
turn to each other, so that the load is evenly distributed around
the turn.
2. high speed refrigerated centrifuge load the solution, according
to a variety of centrifuge concrete operation instructions,
according to the stay of the nature and volume of centrifugal
liquid to choose suitable centrifuge tube, some centrifugal tube
without cover, liquid can not put too much, which prevent the
centrifugal, turn imbalance, rust or corrode, and preparation of
ultracentrifuge centrifuge tube, is often required must be filled
with liquid, so as to avoid the centrifugal sag deformation at the
top of the plastic centrifuge tube. , must check carefully after
each use and head, timely clean, dry, turn is should focus on the
protection of parts in the centrifuge, be careful when you move,
not collision, avoid the scars, turn a long time need not when, to
be coated with a layer of polishing wax protection, it is forbidden
to use significant centrifugal pipe deformation, damage and aging.
3. If you want to in the below room temperature under the
temperature of the centrifugal. Head should be placed in the
refrigerator before use or in the turn of the centrifuge indoor
precooling.
4. Shall not be arbitrarily in the process of centrifugal leave,
should observe whether the instrument on the centrifuge to work
properly, if there is any abnormal sound is necessary to stop the
machine immediately to check and timely troubleshooting.